產品明細
RT-ZC05B Current Probe
電流探棒
產品簡述
♦ 頻寬: 2MHz
♦ 感度: 0.01 V/A
♦ 動態範圍: 500 A (RMS), 700 A (peak)
♦ 上升時間: 175 ns
詢價
產品詳細介紹
Product Introduction
CURRENT PROBES
Rohde&Schwarz current probes enable accurate, non-intrusive measurement of DC and AC currents. Different models are available to measure currents in the range of 1 mA to 2000 A with a maximum bandwidth of up to 120 MHz.
DC and AC measurements without circuit interruption
The R&S®RT-ZC current probes precisely measure direct and alternating current without interrupting the power circuit for the measurement. The extra-large opening on the R&S®RT-ZC10 accommodates conductors of up to 20 mm in diameter. The R&S®RT-ZC10 can measure peak currents up to 300 A (500 A for a single pulse). When measuring low-amplitude, high-frequency currents, the more compact R&S®RT-ZC20 with a measurement bandwidth of 100 MHz is ideal.
The R&S®RT-ZC31 allows switching between three different sensitivity ranges to cover a very broad dynamic range with high bandwidth.
Robust design and easy operation
Rohde&Schwarz current probes are characterized by their robust design and easy operation. The degauss and offset correction is performed directly at the probe connector. The compact R&S®RT-ZA13 probe power supply supplies up to four current probes. The current probes can be selected as predefined probes on the R&S®RTO, R&S®RTE, R&S®RTM and R&S®RTA oscilloscopes.
Easy deskewing for simultaneous current and voltage measurements
For meaningful measurements on power electronics, there must be no time delay (skew) between the current and the voltage measurements. The R&S®RT-ZF20 power deskew and calibration test fixture provides a variety of test signals that can be used to easily compensate for skew between Rohde&Schwarz current and voltage probes. Power to the power deskew and calibration test fixture is supplied via the oscilloscope's USB port.
Model
Bandwidth
Sensitivity
Dynamic range
Rise time
Comment
Probes
R&S®RT-ZC02
20 kHz
0.01 V/A, 0.001 V/A
±200 A, ±2000 A
5 µs
battery powered
R&S®RT-ZC03
100 kHz
0.1 V/A 20 A (RMS),
±30 A (peak)
1 µs
battery powered
R&S®RT-ZC05B
2 MHz
0.01 V/A
500 A (RMS), 700 A (peak)
175 ns
power supply via Rohde&Schwarz probe interface
R&S®RT-ZC10
10 MHz
0.01 V/A
150 A (RMS), ±300 A (peak), ±500 A (peak) (single pulse)
35 ns
power supply via R&S®RT-ZA13
R&S®RT-ZC10B
10 MHz
0.01 V/A
150 A (RMS), ±300 A (peak), ±500 A (peak) (single pulse)
35 ns
power supply via Rohde&Schwarz probe interface
R&S®RT-ZC15B
50 MHz
0.1 V/A
30 A (RMS), ±50 A (peak)
7 ns
power supply via Rohde&Schwarz probe interface
R&S®RT-ZC20
100 MHz
0.1 V/A
30 A (RMS), ±50 A (peak)
3.5 ns
power supply via R&S®RT-ZA13
R&S®RT-ZC20B
100 MHz
0.1 V/A
30 A (RMS), ±50 A (peak)
3.5 ns
power supply via Rohde&Schwarz probe interface
R&S®RT-ZC30
120 MHz
1 V/A
5 A (RMS), 7.5 A (peak)
2.9 ns
power supply via R&S®RT-ZA13
R&S®RT-ZC31
120 MHz
0.1 V/A, 1 V/A, 10 V/A
30 A (RMS), 5 A (RMS), 0.5 A (RMS)
2.9 ns
power supply via R&S®RT-ZA13
Accessories
R&S®RT-ZF20
power deskew and calibration test fixture
R&S®RT-ZA13
external power supply for up to four Rohde&Schwarz current probes
回列表頁
商品諮詢
TOP
購物須知
TOP