Frequency range | R&S®CableRider ZPH (one-port model .02) | 2 MHz to 3 GHz |
| with R&S®ZPH-B4 option | 2 MHz to 4 GHz |
| R&S®CableRider ZPH (two-port combi model .12) |
| with R&S®ZPH-K1 option | 5 kHz to 3 GHz |
| with R&S®ZPH-B4 and R&S®ZPH-K1 options | 5 kHz to 4 GHz |
Frequency resolution | | 1 Hz |
Spectrum measurement with combi model .12 only, with R&S®ZPH-K1 option |
Spectral purity, SSB phase noise | f = 500 MHz, carrier offset 30 kHz | < –88 dBc (1 Hz), typ. –95 dBc (1 Hz) |
| f = 500 MHz, carrier offset 100 kHz | < –98 dBc (1 Hz), typ. –105 dBc (1 Hz) |
| f = 500 MHz, carrier offset 1 MHz | < –118 dBc (1 Hz), typ. –125 dBc (1 Hz) |
Displayed average noise level (DANL) | 0 dB RF attenuation, termination 50 Ω, RBW = 1 kHz, VBW = 10 Hz, sample detector, log scaling, normalized to 1 Hz |
| frequency preamplifier = off | |
| 1 MHz to 10 MHz | < –130 dBm, typ. –135 dBm |
| 10 MHz to 1 GHz | < –142 dBm, typ. –146 dBm |
| 1 GHz to 4 GHz | < –140 dBm, typ. –144 dBm |
| frequency preamplifier = on | |
| 1 MHz to 10 MHz | < –150 dBm, typ. –160 dBm |
| 10 MHz to 3 GHz | < –158 dBm, typ. –163 dBm |
| 3 GHz to 4 GHz | < –156 dBm, typ. –161 dBm |
Individual measurements | | reflection (S11), one-port cable loss, distance-to-fault |
Port output power | controlled via tracking generator attenuation | –10 dBm (nom.) |
Maximum permissible spurious signal | measurement = reflection (S11)/one-port cable loss/distance-to-fault analysis | +17 dBm (nom.) |
Data points | Selectable | 101 to 2501 |
Reflection measurement S11 |
Corrected directivity with R&S®ZN-Z103 option | 2 MHz ≤ f ≤ 4 GHz (with R&S®ZPH-B4 option) | > 42 dB (nom.) |
Measurement speed | | 0.3 ms/point |
Result formats | | magnitude, VSWR, magnitude and distance-tofault, VSWR and distance-to-fault |
One-port cable loss measurement |
Result format | | magnitude |
Range | Selectable | 1/2/5/10/20/50/100/120/150 dB |
Distance-to-fault analysis |
Result formats | | return loss (dB), VSWR |
Fault resolution | | 1.5 m × 108 m × velocity factor/span |
Maximum cable length | depending on cable loss | 1500 m (nom.) |
Maximum rated input levels |
DC voltage | | 50 V |
CW RF power | model .02: port 1 (power meter input) | 30 dBm |
| model .12: port 1 (RF input) | 20 dBm |
| port 2 (reflectometer input) | 23 dBm |
General data |
Display resolution | WVGA | 800 × 480 pixel |
Battery (R&S®HA-Z306 option) | Capacity | 72 Wh |
| Voltage | 11.25 V (nom.) |
Operating time with new, fully charged battery | one-port model .02 | 9 h |
| two-port combi model .12, spectrum analyzer mode | 9 h |
| two-port combi model .12, cable and antenna analyzer mode | 6.5 h |
Dimensions | W × H × D | 202 mm × 294 mm × 76 mm (8.0 in × 11.6 in × 3 in) |
Weight | | 2.5 kg (5.5 lb) |