產品明細

HMP4000

電源供應器

    產品簡述
    ♦ 三通道或四通道機型(HMP4030&4040)
    ♦ 最大輸出功率: 384W
    每通道最大輸出電壓: 32V; 串聯操作下可提供更高電壓
    ♦ 每通道輸出最大功率: 160W
    ♦ 每通道輸出最大電流: 10A
    ♦ 電子保險絲
    (OCP), 過電壓保護(OVP), 過熱保護(OTP)

      產品詳細介紹Product Introduction

      Up to four channels in a single instrument

      The R&S®HMP power supplies are primarily designed for industrial use. With two, three or four output channels and up to 10 A output current per channel, these rugged instruments are ideal for a wide variety of applications. They offer high efficiency with low residual ripple and many protection functions.
      The R&S®HMP power supply family consists of four models. The R&S®HMP2020 two-channel power supply and the R&S®HMP2030 three-channel power supply deliver up to 188 W total output power, the three-channel R&S®HMP4030 and the four-channel R&S®HMP4040 offer a maximum output power of 384 W. The total load can be distributed as desired over the separate channels. Depending on the model, up to 80 W or 160 W of channel power is available – in any voltage/current distribution. Up to four galvanically isolated, floating output channels with overload and short-circuit protection are available, depending on the instrument type. The channels can be connected in series or parallel to obtain higher voltages or currents. The R&S®HMP4040, for example, offers a maximum voltage of 128 V or a maximum current of 40 A. All basic functions of the R&S®HMP power supplies are directly accessible on the front panel. The rotary knob plays a key role. It is used to set the voltage, current and limit values for the various protection functions.
      The channel keys light up in different colors to indicate the operating conditions of the channels. All channels can be simultaneously switched on or off with the “Output” key, which lights up white when it is "on". Active outputs light up green in constant voltage mode and red in constant current mode. The R&S®HMP power supplies offer a variety of protection functions to prevent damage to the instrument and the DUT. You can separately set the maximum current (electronic fuse, overcurrent protection/OCP) or the maximum voltage (overvoltage protection/OVP) for each channel. The output channels switch off when either of their set limits is reached. Overtemperature protection (OTP) prevents the instrument from overheating. In industrial applications, power supplies are often installed in 19-inch racks. The R&S®HZ42 and R&S®HZP91 rack adapters are available for this purpose. Additional connections for all channels (including sense lines) are provided on the rear panel to simplify use in system cabinets. The R&S®HMP power supplies are equipped with a dual USB/LAN interface as standard. This interface can optionally be replaced by a dual RS-232/USB interface or a GPIB (IEEE488) interface.


      Available models
      ModelsNumber of output channelsMax. output powerOutput voltage per channelOutput current per channel
      R&S®HMP40303384 W0 V to 32 V10 A
      R&S®HMP40404384 W0 V to 32 V10 A
      Features
      • R&S®HMP2020/HMP2030 with 2/3 channels and 188 W total output power
      • R&S®HMP4030/HMP4040 with 3/4 channels and 384 W total output power
      • Maximum output voltage of 32 V per channel; higher voltages possible in serial operation
      • High output currents up to 5 A/10 A (depending on the model); higher currents possible in parallel operation
      • Linear postregulation for low residual ripple
      • Electronic fuse (OCP), adjustable maximum voltage (OVP), overtemperature protection (OTP)
      • Dual USB/LAN interface as standard; RS-232/USB or GPIB (IEEE488) optional
      • Rear panel connections, including sense lines, for all channels

      • More than meets your daily needs
        • All channels galvanically isolated and floating
        • All channels have the same voltage range
        • All channels have overload and short-circuit protection
        • Parallel and serial operation
        • Constant voltage and constant current modes
        • Tracking and link functions
        • Protection functions to safeguard instrument and DUT
        • Modern instrument concept: small, compact and quiet

      • Easy operation
        • Intuitive to use
        • Color coding of operating states
        • EasyArb function for all channels
        • Save and recall instrument settings

      • Ideal for labs and test systems
        • Tailored for use in labs and system racks
        • Sense function for more stringent accuracy requirements
        • Remote control of instrument functions

      Specifications
      All data is valid at 23°C (–3°C/+7°C) after 30 minutes warm-up time.

      Electrical specifications
      OutputsAll channel outputs are galvanically isolated and not connected to ground.
      Number of output channelsR&S®HMP20202
      R&S®HMP20303
      R&S®HMP40303
      R&S®HMP40404
      Total output powerR&S®HMP2020/HMP2030max. 188 W
      R&S®HMP4030/HMP4040max. 384 W
      Maximum output power per channelR&S®HMP2020channel 1: 160 W; channel 2: 80 W
      R&S®HMP203080 W
      R&S®HMP4030/HMP4040160 W
      Output voltage per channelall models0 V to 32 V
      Maximum output current per channelR&S®HMP2020channel 1: 10 A; channel 2: 5 A
      R&S®HMP20305 A
      R&S®HMP4030/HMP404010 A
      Maximum voltage in serial operationR&S®HMP202064 V
      R&S®HMP2030/HMP403096 V
      R&S®HMP4040128 V
      Maximum current in parallel operationR&S®HMP2020/HMP203015 A
      R&S®HMP403030 A
      R&S®HMP404040 A
      Voltage ripple3 Hz to 100 kHz< 250 μV (RMS), typ.<150 μV (RMS)
      3 Hz to 20 MHztyp. < 1.5 mV (RMS)
      Current ripple< 1 mA (RMS)
      Load regulationload change from 10% to 90%
      Voltage±(% of output + offset)< 0.01 % + 2 mV
      Current±(% of output + offset)< 0.01 % + 250 μA
      Load recovery timeto within ± 10 mV of the set nominal voltage< 1 ms
      Line regulation±10% change in mains voltage
      Voltage±(% of output + offset)< 0.01% + 2 mV
      Current±(% of output + offset)< 0.01% + 250 μA
      Programming resolution
      Voltage1 mV
      CurrentR&S®HMP2020 channel 1 (10 A)< 1 A: 0.2 mA; ≥ 1 A: 1 mA
      R&S®HMP2020 channel 2 (5 A)< 1 A: 0.1 mA; ≥ 1 A: 1 mA
      R&S®HMP2030< 1 A: 0.1 mA; ≥ 1 A: 1 mA
      R&S®HMP4030/HMP4040< 1 A: 0.2 mA; ≥ 1 A: 1 mA
      Programming accuracy
      Voltage±(% of output + offset)< 0.05% + 5 mV
      Current±(% of output + offset)< 0.1% + 5 mA
      Output measurements
      Measurement functionsvoltage, current
      Readback resolution
      Voltage1 mV
      CurrentR&S®HMP2020 channel 1 (10 A)< 1 A: 0.2 mA; ≥ 1 A: 1 mA
      R&S®HMP2020 channel 2 (5 A)< 1 A: 0.1 mA; ≥ 1 A: 1 m
      R&S®HMP2030< 1 A: 0.1 mA; ≥ 1 A: 1 mA
      R&S®HMP4030/HMP4040< 1 A: 0.2 mA; ≥ 1 A: 1 mA
      Readback accuracy
      Voltage±(% of output + offset)< 0.05% + 5 mV
      Current±(% of output + offset)< 0.1% + 2 mA
      Output measurements
      Temperature coefficient (per °C)5°C to 20°C and 30°C to 40°C
      Voltage±(% of output + offset)0.01% + 2 mV
      Current±(% of output + offset)0.02% + 3 mA
      Sense functionyes, for each channel
      Maximum sense compensation1 V
      Ratings
      Maximum voltage to earth150 V (peak)
      Maximum counter-voltagevoltage with same polarity connected to the outputs33 V
      Maximum reverse voltagevoltage with opposite polarity connected to the outputs0.4 V
      Maximum reverse currentfor 5 minutes max.5 A
      Remote control mode
      Command processing time< 50 ms
      Protection functions
      Overvoltage protectionconfigurable for each channel
      Overcurrent protection (electronic fuse)configurable for each channel
      Response time(Iload > Iresponse × 2)< 10 ms
      Fuse linking (FuseLink function)yes
      Fuse delay timeconfigurable for each channel0 ms to 250 ms (10 ms increments)
      Overtemperature protectionyes
      Special functions
      Arbitrary function (EasyArb)
      Parametervoltage, current, time
      Maximum number of points128
      Dwell time10 ms to 60 s
      Repetitioncontinuous or burst mode 1 to 255 repetitions
      Data memorynon-volatile memory for three arbitrary functions and ten instrument settings
      Display and interfaces
      DisplayR&S®HMP2020/HMP2030240 pixel × 64 pixel LCD
      R&S®HMP4030/HMP4040240 pixel × 128 pixel LCD
      Front panel connectionschannel outputs4 mm safety sockets
      Rear panel connectionsconnector block with 4 lines per channel
      Remote control interfacesstandarddual interface LAN/USB
      optionaldual interface USB/RS-232 (R&S®HO720)
      optionalIEEE488 (GPIB) (R&S®HO740)
      General data
      Environmental conditions
      Temperatureoperating temperature range+5°C to +40°C
      storage temperature range–20°C to +70°C
      Humiditynoncondensing5% to 80%
      Power rating
      Mains nominal voltage115 V/230 V (±10%); CAT II
      Mains frequency50 Hz to 60 Hz
      Maximum power consumptionR&S®HMP2020/HMP2030300 W
      R&S®HMP4030/HMP4040600 W
      Mains fuses (115 V power source)R&S®HMP2020/HMP20302 × T6.3H/250 V
      R&S®HMP4030/HMP40402 × T10H/250 V
      Mains fuses (230 V power source)R&S®HMP2020/HMP20302 × T3.15H/250 V
      R&S®HMP4030/HMP40402 × T5H/250 V
      Product conformity
      Electromagnetic compatibilityEU:
      in line with EU EMC Directive 2014/30/EU
      in line with EU EMC Directive 2014/53/EU
      applied harmonized standards:
      ❙ EN61326-1: 2013
      ❙ EN61326-2-1: 2013
      ❙ EN55011: 2016 (Class A)
      ❙ IEC61000-3-2 2014 (Class B)
      ❙ IEC61000-3-3: 2013
      ❙ EN50581:2012 (RoHS)
      ❙ EN300 328 V2.1.1
      Korea❙ KN61000-4-11: 2008
      Electrical safetyEU:
      in line with Low Voltage Directive 2006/95/EC
      applied harmonized standards:
      EN61010-1:2010
      USA, CanadaCSA C22.2 No. 61010-1:2012
      Mechanical resistance
      Vibrationsinusoidal5 Hz to 55 Hz, 0.3 mm amplitude const., 55 Hz to 155 Hz, 0.5 g const., in line with EN 60068-2-6: 2008
      random8 Hz to 500 Hz, 1.2 g (RMS), in all 3 axes, in line with EN60068-2-64: 2008
      Mechanical data
      Dimensions (W × H × D)R&S®HMP2020/HMP2030285 mm × 95 mm × 405 mm
      (11.22 in × 3.74 in × 15.94 in)
      R&S®HMP4030/HMP4040285 mm × 136 mm × 405 mm
      (11.22 in × 5.35 in × 15.94 in)
      WeightR&S®HMP20207.8 kg (17.2 lb)
      R&S®HMP20308.0 kg (17.6 lb)
      R&S®HMP403012.4 kg (27.3 lb)
      R&S®HMP404012.8 kg (28.2 lb)
      Rack installationR&S®HMP2020/HMP2030R&S®HZ42 option
      R&S®HMP4030/HMP4040R&S®HZP91 option
      Recommended calibration intervaloperation 40 h/week over entire range of speci[1]fied environmental conditions 1 year