產品明細

LCX

LCR電橋

    產品簡述
    ♦ 頻率範圍: 4Hz ~ 10MHz
    ♦ 阻抗測試基本精度: ±0.05 %

    ♦ 相位測試基本精度: ±0.03°
    ♦ DC直流偏壓: up to 40V
    ♦ 具備Data logging功能

      產品詳細介紹Product Introduction

      AT A GLANCE

      The R&S®LCX LCR meters are versatile, extremely accurate and perform measurements quickly. They are ideal for challenging applications in research, development and production. Two instrument models and various options cover applications with a test signal frequency of up to 10 MHz. Internal and external bias functions, comprehensive analysis options and versatile test fixtures expand the wide range of possible applications.

      The R&S®LCX100 LCR meter covers the frequency range from 4 Hz to 300 kHz. The R&S®LCX200 has an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed. All instruments offer DC measurements as well. Internally generated voltages of up to 10 V cover most applications. Optionally, bias voltages of up to 40 V can be applied externally. A fast logging function records all measured values up to 10 times per second. Dynamic impedance measurements can be performed using the advanced analysis function. In these sweep measurements, the impedance values are determined for a series of frequency values or other parameters.

      Measurements can be triggered and controlled externally via digital I/O ports. The binning function enables the measured components to be sorted by their values into up to eight categories. The large capacitive touchscreen is the central element for modern and intuitive operation of the instruments and enables the graphical display of the measurement results. Remote controllability and rack installation predestine the R&S®LCX for system applications.


      Features:
      • Universal LCR meter
        • Fast, accurate and versatile
        • Selectable frequency range
        • Test signals for all requirements
        • DC bias
        • Measurement functions
        • Data logging function
      • Options for advanced applications
        • R&S®LCX-K106 advanced analysis functions
        • R&S®LCX-K107 digital I/O ports and binning function
        • R&S®LCX-K108 extended bias functions
        • R&S®LCX-K201/-K210 frequency upgrade to 1 MHz/10 MHz
      • Easy operation
        • High-resolution touchscreen
        • Graphical representation of measurements
        • Save and recall instrument settings
      • Test fixtures
        • R&S®LCX-Z1 test fixture for axial/radial lead type devices
        • R&S®LCX-Z2 Kelvin clip lead
        • R&S®LCX-Z3 test fixture for SMD components
        • R&S®LCX-Z4 test tweezers for SMD components
        • R&S®LCX-Z5 transformer test cables
        • R&S®LCX-Z11 BNC extension
      • Ideal for use in labs and test systems
        • Tailored for use in labs and system racks
        • Full remote capabilities
        • Advanced instrument design: compact form factor, quiet operation

      Specifications:

      Test signals
      Test signal frequency
      Frequency range R&S®LCX100 DC, 4 Hz to 300 kHz
      R&S®LCX200 DC, 4 Hz to 500 kHz
      R&S®LCX200 with R&S®LCX-K201 option DC, 4 Hz to 1 MHz
      R&S®LCX200 with R&S®LCX-K210 option DC, 4 Hz to 1 MHz (at 10 Ω),
      DC, 4 Hz to 10 MHz (at 100 Ω)
      Frequency resolution4 Hz to < 1 kHz: 0.1 Hz,
      1 kHz to < 10 kHz: 1 Hz,
      10 kHz to < 100 kHz: 10 Hz,
      100 kHz to < 1 MHz: 100 Hz,
      1 MHz to 10 MHz: 1 kHz
      Frequency accuracy ±100 ppm
      Test signal modes
      Modes open voltage (V), short current (C),
      DC resistance (Rdc)
      Test signal impedance
      Source impedance 100 Ω, 10 Ω
      Source impedance accuracy ±(% of setting + offset) < 2% + 200 mΩ (nom.)
      Test signal levelSpecifications are valid for impedance measurements (AC measurements) as well as for Rdc measurements.
      Test signal voltage (at 100 Ω) without load
      Voltage range ≤ 1 MHz: 100 mV to 10 V1),
      ≤ 5 MHz: 100 mV to 2 V,
      > 5 MHz: 100 mV to 1 V
      Voltage resolution ≤ 2 V: 1 mV,
      > 2 V: 10 mV
      Voltage setting accuracy in mode V±(% of setting + offset)≤ 1 MHz: < 5% + 2.5 mV,
      > 1 MHz: < 10% + 5 mV,
      > 5 MHz: < 15% + 10 mV
      Test signal voltage (at 10 Ω) without load
      Voltage range≤ 100 kHz: 100 mV to 2 V,
      > 100 kHz to ≤ 1 MHz: 100 mV to 1 V
      Voltage resolution 1 mV
      Voltage setting accuracy in mode V ±(% of setting + offset) < 5% + 2.5 mV (meas.)
      Test signal current (at 100 Ω)
      Current range≤ 1 MHz: 1 mA to 100 mA,
      > 1 MHz to ≤ 5 MHz: 1 mA to 20 mA,
      > 5 MHz: 1 mA to 10 mA
      Current resolution≤ 20 mA: 10 µA,
      > 20 mA: 100 µA
      Current setting accuracy in mode C ±(% of setting + offset) ≤ 1 MHz: < 5% + 25 µA (meas.),
      > 1 MHz: < 10% + 50 µA (meas.)
      Test signal current (at 10 Ω)
      Current range ≤ 100 kHz: 10 mA to 200 mA,
      > 100 kHz to ≤ 1 MHz: 10 mA to 100 mA
      Current resolution 100 µA
      Current setting accuracy in mode C ±(% of setting + offset) < 5% + 25 µA (meas.)
      Test signal monitorAC component voltage, current
      Voltage monitor accuracy ±(% of measured value + offset) ≤ 1 MHz: ≤ 2.5% + 5 mV
      Current monitor accuracy ±(% of measured value + offset) ≤ 1 MHz: ≤ 2.5% + 50 µA,
      > 1 MHz: ≤ 5% + 100 µA
      1) If a 1 m long test cable is used, the maximum test voltage is reduced to 9.5 V.

      DC bias signals
      Internal bias voltage
      Voltage range at 100 Ω source impedance 0 V to 10 V (DC)
      at 10 Ω source impedance 0 V to 2 V (DC)
      Voltage resolution 10 mV
      Voltage setting accuracy ±(% of setting + offset) test signal < 5 V: < (1% + 4 mV ) × Kt ,
      test signal ≥ 5 V: < (1% + 12 mV ) × Kt
      Kt (temperature coefficient) +23°C (–3°C/+7°C) 1
      other temperatures 1 + 0.1 × abs(Ta – 23)
      Internal bias current R&S®LCX-K108 required
      Current range 0 mA to 200 mA (DC)
      Current resolution 1 mA
      Current setting accuracy ±(% of setting + offset) < 1% + 1 mA
      Maximum DC resistance of DUT at 100 Ω source impedance 50 Ω
      at 10 Ω source impedance 5 Ω
      External bias voltage R&S®LCX-K108 required
      Voltage range 0 V to +40 V (DC)
      Voltage monitor resolution 11 mV
      Measurement accuracy ±(% of measured value + offset) < 2.5% + 44 mV
      Measurements
      Measurement functions L, C, R, Z, X, Y, G, B, D, Q, Θ, M, N, Rdc
      Impedance measurement range at 100 Ω source impedance 100 mΩ to 100 MΩ
      at 10 Ω source impedance 10 mΩ to 100 Ω
      Phase measurement range –180° to +180°
      Range selection auto, manually
      Cable length 0 m, 1 m
      Maximum test cable length 1 m
      Measurement time test frequency ≥ 1 kHz fast: ≤ 15 ms,
      medium: ≤ 100 ms,
      slow: ≤ 500 ms
      Averaging 1 to 256 measurements
      Compensation function open, short, load
      Open limits ≤ 5 MHz: min. 100 kΩ,
      > 5 MHz: min. 10 kΩ
      Short limits ≤ 5 MHz: max. 3 Ω,
      > 5 MHz: max. 10 Ω