產品明細

NGM200

電源供應器

    產品簡述
    ♦ 所有通道均為電位隔離且不接地
    所有通道的電壓, 電流及功率等效
    最大輸出功率: 120W
    每通道最大輸出電壓: 20V
    每通道輸出最大電流: 6A
    解析度: 1uV/10nA
    ♦ 電池模擬功能
    高速資料紀錄: 500ksample/s

    ♦ 電子保險絲(OCP), 過電壓保護(OVP), 過功率保護(OPP), 過熱保護(OTP)

      產品詳細介紹Product Introduction

      High-speed accuracy

      The single-channel R&S®NGM201 and the two-channel R&S®NGM202 deliver up to 60 W of output power per channel. The output channels are floating, galvanically isolated and protected against overload and short circuits. With four measurement ranges for current and a resolution of up to 6½ digits when measuring voltage, current and power, the R&S®NGM200 power supplies are perfect for characterizing devices that have low power consumption in standby mode and high current in full load operation. In many cases, an additional digital multimeter is no longer necessary. Thanks to their fast recovery time of < 30 µs, their minimum overshoot even during a demanding load change and fast impedance regulation, the R&S®NGM200 power supplies are ideal for powering IoT devices and other battery-operated devices. With an acquisition rate of up to 500000 samples per second, even extremely fast variations in voltage or current can be captured. The linear two-quadrant design of the output stages allows the R&S®NGM200 power supply series to operate as a source and sink with minimum residual ripple and noise, ideally supporting the development of power amplifiers and MMICs. The optional battery simulation functionality provides test conditions that imitate the use of a real battery.

      Available models
      ModelsNumber of output channelsMax. output powerOutput voltage per channelOutput current per channel
      R&S®NGM201160 W0 V to 20 V≤ 6 V: 0 A to 6 A
      > 6 V: 0 A to 3 A
      R&S®NGM2022120 W0 V to 20 V
      ≤ 6 V: 0 A to 6 A
      > 6 V: 0 A to 3 A
      Features
      • Technology for challenging tasks
        • Fast load regulation
        • Minimum residual ripple and low noise
        • Readings with up to 6½ digit resolution
        • Digital voltmeter functionality
        • Galvanically isolated, floating channels
        • Output stage isolated with relays
        • Two quadrants: operates as source and sink
        • Constant voltage, constant current and constant resistance modes
        • Variable output impedance
        • High-speed acquisition (FastLog functionality)
        • Protection functions to safeguard instrument and DUT
        • Safety limits to safeguard the DUT

      • Battery simulation
        • Battery models 
        • Battery simulation

      • Easy operation
        • High-resolution touchscreen
        • Color coding of operating modes
        • QuickArb function
        • EasyRamp function
        • Save and recall instrument settings

      • Ideal for use in labs and test systems
        • Tailored for use in labs and system racks
        • Remote sensing
        • Front and rear connectors
        • Full remote capabilities
        • Fast on the bus and on the bench
        • Advanced instrument design: compact form factor, quiet operation

      Specifications

      Electrical specifications
      OutputsThe channel outputs are galvanically isolated and not connected to ground.
      Number of output channels R&S®NGM2011
      R&S®NGM2022
      Total output power R&S®NGM201max. 60 W
      R&S®NGM202max. 120 W
      Maximum output power per channel60 W
      Output voltage per channel0 V to 20 V
      Maximum output current per channel ≤ 6 V output voltage6 A
      > 6 V output voltage 3 A
      Maximum voltage in serial operation R&S®NGM20240 V
      Maximum current in parallel operation R&S®NGM202, ≤ 6 V output voltage12 A
      R&S®NGM202, > 6 V output voltage6 A
      Adjustable output impedance–50 mΩ to 100 Ω
        Increments1 mΩ
        Recovery time≤ 2 Ω, resistive load< 200 µs
      > 2 Ω, resistive load< 10 ms
      Voltage ripple and noise 20 Hz to 20 MHz< 500 µV (RMS),
      < 2 mV (peak-to-peak) (meas.)
      Current ripple and noise 20 Hz to 20 MHz< 1 mA (RMS) (meas.)
      Electronic loadyes, R&S®NGM202: both channels
        Maximum sink power R&S®NGM20160 W
      R&S®NGM202120 W (60 W per channel)
        Maximum sink current per channel3 A
        Sink modesconstant voltage, constant current, constant resistance
        Constant resistance range0 Ω to 10 kΩ (0.1 Ω increments)
      Load regulationload change: 10% to 90%
      Voltage±(% of output + offset)< 0.01% + 1 mV
      Current±(% of output + offset)< 0.01% + 0.1 mA
      Load recovery timeregulation to within ±20 mV of the set voltage< 30 µs (meas.)
      Rise time10% to 90% of rated output voltage, resistive loadfull load:< 125 µs
      no load: < 125 µs
      Fall time90% to 10% of rated output voltage, resistive loadfull load: < 125 µs
      no load: < 125 µs
      Programming resolution
      Voltage1 mV
      Current0.1 mA
      Programming accuracy
      Voltage±(% of setting + offset)< 0.02% + 3 mV
      Current±(% of setting + offset)< 0.05% + 2 mA
      Output measurements
      Measurement functionsvoltage, current, power, energy
      Readback resolution
      Voltage20 V range: 10 μV
      5 V range: 5 μV
      Current10 A range: 10 μA
      1 A range: 1 μA
      100 mA range: 100 nA
      10 mA range: 10 nA
      Readback accuracy
      Voltage±(% of output + offset) 20 V range: < 0.02% + 2 mV
      5 V range: < 0.02% + 500 μV
      Current ±(% of output + offset)10 A range: < 0.05% + 250 μA
      1 A range: < 0.05% + 1 mA
      100 mA range: < 0.05% + 100 μA
      10 mA range: < 0.05% + 15 μA
      Temperature coefficient (per °C)+5 °C to +20 °C and +30 °C to +40 °C
      Voltage0.15 × specification/°C
      Current0.15 × specification/°C
      Remote sensingyes, R&S®NGM202: both channels
      Maximum sense compensation2 V (meas.)
      Ratings
      Maximum voltage to ground250 V DC
      Maximum countervoltage voltage with the same polarity connected to the outputs22 V
      Maximum reversevoltage voltage with opposite polarity connected to the outputs0.5 V
      Maximum reverse current for 5 minutes max. 1 A
      Ratings
      Command processing time typ. < 6 ms
      Protection functions
      Overvoltage protectionadjustable, R&S®NGM202: both channels
        Programming resolution1 mV
      Overpower protectionadjustable, R&S®NGM202: both channels
      Overcurrent protection (electronic fuse)adjustable, R&S®NGM202: both channels
        Programming resolution0.1 mA
        Response time (Iload > Iresp × 2) at Iload ≥ 2 A< 1.5 ms
        Fuse linking (FuseLink function)R&S®NGM202yes
        Fuse delay at output-on for R&S®NGM202: both channels0 ms to 10 s (1 ms increments)
        Fuse delay timefor R&S®NGM202: both channels0 ms to 10 s (1 ms increments)
      Overtemperature protectionyes
      Special functions
      Output ramp function EasyRamp
      EasyRamp time10 ms to 10 s (10 ms increments)
      Output delay
      Synchronicity R&S®NGM202typ. < 25 μs
      Delay per channel1 ms to 10 s (1 ms increments)
      Arbitrary function QuickArb
      Parametersvoltage, current, time
      Maximum number of points 4096
      Dwell time1 ms to 20 h (1 ms increments)
      Repetitioncontinuous or burst mode with 1 to 65535 repetitions
      Triggermanually via the keyboard, via remote control or via optional interface
      Statistics (sampling time) Voltageminimum, maximum, average (2 µs)
      Currentminimum, maximum, average (2 µs)
      Powerminimum, maximum, average (2 µs)
      Energy(64 ms)
      Digital trigger and control interfacesdigital I/O, R&S®NGM-K103
      Maximum voltage (IN/OUT)24 V
      Pull-up resistors (IN/OUT) connected to 3.3 V 20 kΩ
      Input levelLow < 0.8 V
      High> 2.4 V
      Maximum drain current (OUT) 500 mA
      Data logging standard mode
      Maximum acquisition rate each recorded sample is the average of 50000 measured values 2)10 sample/s
      Memory depthinternal 800 Mbyte or external memory size
      Voltage resolution see readback resolution
      Voltage accuracysee readback accuracy
      Current resolution see readback resolution
      Current accuracysee readback accuracy
      Data logging fast modeFastLog
      Maximum acquisition rate for voltage, current, DVM input500 ksample/s (2 μs)
      Memory depthexternal memory size
      Voltage resolution20 V range: 20 μV
      5 V range: 5 μV
      DVM input: 30 μV
      Voltage accuracy±(% of output + offset)20 V range: < 0.02% + 2 mV
      5 V range: < 0.02% + 500 μV
      DVM input: < 0.02% + 2 mV
      Current resolution10 A range: 20 μA
      1 A range: 2 μA
      100 mA range: 200 nA
      10 mA range: 20 nA
      Current accuracy±(% of output + offset)10 A range: < 0.05% + 2.5 mA
      1 A range: < 0.05% + 1 mA
      100 mA range: < 0.05% + 100 μA
      10 mA range: < 0.05% + 15 μA
      Digital voltmeter input optional, R&S®NGM-K104
      DVM voltage –5 V to +23 V
      DVM accuracy±(% of output + offset)< 0.02% + 2 mV
      Display and interfaces
      DisplayTFT 5" 800 × 480 pixel WVGA touch
      Front panel connections R&S®NGM2014 mm safety sockets (channels, sense)
      R&S®NGM2024 mm safety sockets (channels)
      Rear panel connections8-pin connector block per channel
      Remote control interfaces StandardUSB-TMC, USB-CDC (virtual COM port), LAN
      R&S®NGM-K102WLAN
      R&S®NGM-B105IEEE-488 (GPIB)
      General data
      Environmental conditions
      Temperatureoperating temperature range+5°C to +40°C
      storage temperature range–20°C to +70°C
      HumidityNoncondensing5% to 95%
      Power rating
      Mains nominal voltage100 V/115 V/230 V (± 10%)
      Mains frequency50 Hz to 60 Hz
      Maximum power consumption400 W
      Mains fuses2 × T4.0H/250 V
      Product conformity
      Electromagnetic compatibilityEU: in line with Radio Equipment Directive 2014/53/EU applied standards: ► ETSI EN300328 V2.1.1
      ► EN61326-1
      ► EN55011 (Class A)
      ► EN55032 (Class A)
      ► ETSI EN301489-1 V2.2.0
      ► ETSI EN301489-17 V3.2.0
      KoreaKC mark
      Electrical safetyEU: in line with Low Voltage Directive 2014/35/EUapplied harmonized standards: EN61010-1
      USA, CanadaCSA-C22.2 No. 61010-1
      WLAN approvalsAustria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United KingdomCE0682
      SingaporeiMDA standards DB102020
      USA, CanadaFCC, IC
      RoHSin line with EU Directive 2011/65/EUEN50581
      Mechanical resistance
      VibrationSinusoidal5 Hz to 55 Hz, 0.3 mm (peak-to-peak) 55 Hz to 150 Hz, 0.5 g const., in line with EN60068-2-6
      wideband noise8 Hz to 500 Hz, acceleration: 1.2 g (RMS), in line with EN60068-2-64
      Shock40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I
      Mechanical data
      DimensionsW × H × D222 mm × 97 mm × 436 mm
      (8.74 in × 3.82 in × 17.17 in)
      WeightR&S®NGM2017.2 kg (15.9 lb)
      R&S®NGM2027.4 kg (16.3 lb)
      Rack installationR&S®HZN96 option
      Recommended calibration intervaloperation 40 h/week over entire range of specified environmental conditions1 year