DVB-T2 analysis (R&S®ETC-K240), DVB-T/DVB-H analysis (R&S®ETC-K140) and ISDB-T analysis (R&S®ETC-K160) |
Quasi error-free input level range | RF = 500 MHz, RF preselection on, 64QAM, CR 1/2 | typ. –76 dBm to +10 dBm |
Inherent modulation error ratio (MER) | 0 dB RF attenuation, 64QAM non-hierarchical modulation, 8K FFT, 1/32 guard interval, slow channel adaptation |
| level = –30 dBm, RF preselection off |
| RF = 50 MHz to 862 MHz | > 40 dB |
| RF = 500 MHz | typ. 44 dB |
| level = –45 dBm, RF preselection on |
| RF = 50 MHz to 862 MHz | > 38 dB |
| RF = 500 MHz | typ. 43 dB |
Phase noise | RF = 500 MHz |
| ∆f = 30 kHz | < 98 dBc (1 Hz) |
| ∆f = 100 kHz | < 100 dBc (1 Hz) |
| ∆f = 1 MHz | < 125 dBc (1 Hz) |
Noise figure | RF = 500 MHz |
| RF preselection off | < 22 dB, typ. 18 dB |
| RF preselection on | < 14 dB, typ. 11 dB |
Third-order intermodulation (TOI) | 0 dB RF attenuation |
| RF preselection off | typ. +7 dBm |
| RF preselection on | typ. –6 dBm |
Second-harmonic intercept point (SHI) | 50 MHz < RF < 1.5 GHz, 0 dB RF attenuation |
| RF preselection off | typ. +30 dBm |
| RF preselection on | typ. +60 dBm |
Signal level uncertainty | RF < 3.6 GHz | < 1.0 dB, typ. < 0.5 dB |
Frequency uncertainty | internal reference | 2 × 10-6 |
| with the R&S®HA-Z240 GPS receiver | 2.5 × 10-8 |
Spectrum analysis |
Displayed average noise level (DANL) | RF preselection off | typ. –156 dBm (1 Hz) |
| RF preselection on | typ. –165 dBm (1 Hz) |
Resolution bandwidths (RBW) | | 100 Hz to 3 MHz in 1/sequence |
Video bandwidths | | 10 Hz to 3 MHz in 1/sequence |
Trace detectors | | auto peak, max. peak, min. peak, sample, RMS |
Scalar network analysis (R&S®ETC-K10 option) |
Tracking generator output level | | –40 dBm to 0 dBm in 1 dB steps |
Data points | | 631 |
Dynamic range for transmission measurements | | > 70 dB, typ. 90 dB |
Reflection measurements | R&S®FSH-Z2 | 10 MHz to 3 GHz |
| R&S®FSH-Z3 | 10 MHz to 6 GHz |
Power meter |
Terminating power sensors | R&S®FSH-Z1 | 10 MHz to 8 GHz |
| R&S®FSH-Z18 | 10 MHz to 18 GHz |
Directional power sensors | R&S®FSH-Z14 | 25 MHz to 1 GHz |
| R&S®FSH-Z44 | 200 MHz to 4 GHz |
General data |
Operating temperature range | | 5°C to +45°C |
Display | | 14.5 cm (5.7 in) color LCD TFT |
Dimensions | W × H × D | 233 mm × 158 mm × 350 mm (9.2 in × 6.2 in × 13.8 in) |
Weight | | 4.8 kg (10.6 lb) |