Vertical system |
Number of channels | | 2 |
Bandwidth (–3 dB) | R&S®RTC1002 (with R&S®RTC-B220/-B221/-B222/-B223) | 50 MHz/70 MHz/100 MHz/200 MHz/300 MHz |
Rise time (calculated) | R&S®RTC1002 (with R&S®RTC-B220/-B221/-B222/-B223) | 7 ns/5 ns/3.5 ns/1.75 ns/1.15 ns |
Input impedance | | 1 MΩ ± 2% || 14 pF ± 2 pF |
Input sensitivity | maximum bandwidth in all ranges | 1 mV/div to 10 V/div |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment |
| input sensitivity all ranges | 3% |
Acquisition system |
Maximum realtime sampling rate | | 1 Gsample/s, 2 Gsample interleaved |
Acquisition memory | | 1 Msample, 2 Msample interleaved |
Horizontal system |
Timebase range | | 1 ns/div to 100 s/div |
Trigger system |
Trigger types | standard | edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV, HDTV), pattern, timeout |
| option | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN |
Analysis and measurement functions |
QuickView | At the push of a button, internal measurement values are written directly onto the waveform and updated continuously. | peak-to-peak voltage, pos./neg. peak, rise/fall time, mean value, RMS value, time, frequency |
Automated measurements | | burst width, count positive/negative pulses, count falling/ rising edges, mean value, RMS cycle, RMS, mean cycle, peak±, frequency, period, amplitude, base level, pos./neg. overshoot, pulse width, duty cycle±, rise/time, delay, phase |
Waveform mathematics | | addition, subtraction, multiplication, division, FFT |
MSO option |
Digital channels | | 8 (1 logic probe) |
Sampling rate | | 1 Gsample/s |
Acquisition memory | | 1 Msample |
Waveform generator option |
Resolution, sampling rate | | 8 bit, 978 ksample/s |
Amplitude | high Z; 50 Ω | 60 mV to 6 V (Vpp); 30 mV to 3 V (Vpp) |
DC offset | sine | 0.1 Hz to 50 kHz |
| pulse/rectangle and ramp/triangle | 0.1 Hz to 10 kHz |
4-bit pattern generator option |
Programmable pattern | sample time | 20 ns to 42 s, up/down |
| memory depth | 2048 sample |
4-bit counter | frequency | 100 mHz to 50 MHz |
Square wave | frequency | 1 mHz to 500 kHz |
Digital voltmeter |
Measurements | DC, AC + DC (RMS), AC (RMS)resolution | up to 3 digits |
Frequency counter |
Resolution | | 5 digits |
General data |
Screen | | 6.5" VGA color display (640 × 480 pixel) |
Interfaces | | 1 × USB host, USB device, LAN |
Audible noise | maximum sound pressure level at a distance of 0.3 m | 30.4 dB(A) |
Dimensions | W × H × D | 285 mm × 175 mm × 140 mm (11.22 in × 6.89 in × 5.51 in) |
Weight | | 1.7 kg (3.75 lb) |