亞迅科技股份有限公司
代理廠牌
Principals
Rohde & Schwarz
Active Technologies
Haivision (Aviwest)
DekTec
Interra systems
Leader
Lumantek
Meguro
MIK
Murideo
Phabrix
Portrait (CalMAN)
Sencore
Teledyne Lecroy
WellAV
Harkwood
產品應用
Application
基礎儀器需求
數位電視應用
廣播電視應用
物聯網IoT/藍牙BT應用
色彩分析校正應用
實驗室測試需求
最新消息
News
最新消息
關於亞迅
About Us
公司介紹
經營理念
核心價值
人才招募
連絡我們
Contact
search
分類列表
PRODUCTS
產品應用
產品明細
RT-ZHD60 Active Differential High Voltage Probes
高電壓探棒
產品簡述
♦ 頻寬: 100MHz
♦ 衰減係數: 100:1/1000:1
♦ 輸入阻抗: 40 MΩ || 2 pF
♦ 動態範圍: ±6000 V
詢價
產品詳細介紹
Product Introduction
HIGH VOLTAGE PROBES
The Rohde&Schwarz portfolio of high voltage probes includes passive single-ended and active differential probes for voltages up to 6000 V (peak). Different models allow measurements up to CAT IV environments. Differential probes provide an exceptional common mode rejection ratio over a broad frequency range.
200 MHz bandwidth combined with excellent common mode rejection ratio
In order to achieve highest power efficiencies and power densities in switched-mode power supplies, switching loss has to be minimized. This requires the use of modern, fastswitching semiconductors.
With up to 200 MHz bandwidth and an excellent common mode rejection ratio (CMRR) over a broad frequency range, the R&S®RT-ZHD high voltage differential probes are ideal for measurements on fast-switching semiconductors. Extraordinarily low added noise results in high-quality measurements.
Measurements with highest precision
With 0.5% ensured gain accuracy in the signal path and a DC voltmeter (R&S®ProbeMeter) with 0.1% accuracy integrated into the probe head, the R&S®RT-ZHD probes provide the best available precision in their class. Very low drift makes regular calibration during measurements unnecessary.
Up to 2000 V offset capability at highest vertical sensitivity
To measure ripple voltages on the DC link, it is necessary to compensate for high offset voltages and measure with high vertical sensitivities. Due to its integrated offset circuit, the R&S®RT-ZHD probes offer an offset voltage range that is independent of the vertical setting of the oscilloscope and the attenuation factor on the probe. Now you can measure the smallest of ripple voltages on large DC link voltages without compromising sensitivity.
Easy to use and fully integrated into the Rohde&Schwarz oscilloscopes
An integrated, switchable, 5 MHz analog filter, an audible overrange indicator that indicates common mode voltage overrange situations, and automatic range switching make the probe easy to use. The integrated micro button allows you to control the oscilloscope from the probe.
Fully integrated into the oscilloscope, the probe can be remote controlled for automatic testing and does not require an external power supply.
BNC-type differential probes for less demanding applications
For applications where bandwidth is not critical and a cost-effective solution is required, the R&S®RT-ZD01 high voltage differential probe is an excellent choice. It offers 100 MHz bandwidth for voltages up to 1400 V (peak). Due to the BNC interface, it can be connected to any oscilloscope. Power is supplied via the oscilloscope’s USB port or batteries.
Single-ended passive probes for voltages up to 1000 V (RMS) and 6000 V (peak)
If differential measurements are not required, single-ended passive probes are a powerful, cost-effective solution. The R&S®RT-ZH10 and R&S®RT-ZH11 passive high voltage probes provide a bandwidth up to 400 MHz and attenuation factors of 100:1 and 1000:1, respectively. Both probes are designed for RMS voltages up to 1000 V (CAT II) and – when used exclusively for pulse measurements – for peak voltages up to 6000 V (CAT I). Accessories include safety alligator clips, rigid and springloaded tips and protection caps.
Measuring voltages up to 1000 V (RMS) with 500 MHz bandwidth
Measuring in high voltage environments requires special safety precautions in line with the European Low Voltage Directive that depend on the actual measurement environment.
The R&S®ScopeRider RTH lets you safely measure voltages up to 1000 V in CAT III environments or 600 V in CAT IV environments. In combination with the R&S®RT-ZI11 100:1 passive high voltage probe, a bandwidth of 500 MHz is achieved. This makes the solution interesting for measurements on GaN based power electronics components.
Model
Bandwidth
Attenuation factor
Input impedance
Dynamic range
Comment
Passive
R&S®RT-ZH03
250 MHz
100:1
100 MΩ || 6.5 pF
850 V (RMS)
robust 5 mm probe tip
R&S®RT-ZH10
400 MHz
100:1
50 MΩ || 7.5 pF
1000 V (RMS), 6000 V (peak)
1000 V (RMS) CAT II, 5 mm probe tip, spring-loaded
R&S®RT-ZH11
400 MHz
1000:1
50 MΩ || 7.5 pF
1000 V (RMS), 6000 V (peak)
1000 V (RMS) CAT II, 5 mm probe tip, spring-loaded
R&S®RT-ZI11
500 MHz
100:1
100 MΩ || 4.6 pF
1000 V (RMS)
600 V (RMS) CAT IV, 1000 V (RMS) CAT III, 3540 V (RMS) CAT 0, for R&S®Scope Rider RTH only
Active, differential
R&S®RT-ZD01
100 MHz
100:1/1000:1
8 MΩ || 3.5 pF
±1400 V
1000 V (RMS) CAT III
R&S®RT-ZHD07
200 MHz
25:1/250:1
5 MΩ || 2.5 pF
±750 V
300 V (RMS) CAT III
R&S®RT-ZHD15
100 MHz
50:1/500:1
10 MΩ || 2 pF
±1500 V
1000 V (RMS) CAT III
R&S®RT-ZHD16
200 MHz
50:1/500:1
10 MΩ || 2 pF
±1500 V
1000 V (RMS) CAT III
R&S®RT-ZHD60
100 MHz
100:1/1000:1
40 MΩ || 2 pF
±6000 V
1000 V (RMS) CAT III
Accessory
R&S®RT-ZA24
replacement kit for R&S®RT-ZHD probes
回列表頁
商品諮詢
TOP
購物須知
TOP