產品明細

NGL200

電源供應器

    產品簡述
    ♦ 優化電路設計, 負載恢復時間<30us, 迅速調節輸出電壓
    最大輸出功率: 120W
    最大輸出電壓: 20V
    每通道輸出最大電流: 6A
    解析度: 1mV/0.1mA
    ♦ 漣波與雜訊: <500uV

      產品詳細介紹Product Introduction

      High precision source and sink

      Thanks to their high accuracy and fast load recovery time, the R&S®NGL200 power supplies are perfect for challenging applications. Their two-quadrant architecture allows them to function both as a source and a sink to simulate batteries and loads. Their short recovery times enable them to handle fast load changes that occur for example when mobile communications devices switch from sleep mode to transmit mode.
      The single-channel R&S®NGL201 and the two-channel R&S®NGL202 deliver up to 60 W of output power per channel. The output channels are floating, galvanically isolated and protected against overload and short circuits. Thanks to their fast recovery time of < 30 µs and minimum overshoot even during a demanding load change, the R&S®NGL200 power supplies are ideal for powering IoT devices and other battery-operated devices. With a resolution of up to 6½ digits when measuring voltage, current and power, the R&S®NGL200 power supplies are perfect for characterizing devices that have low power consumption in standby mode and high current in full load operation. In many cases, an additional digital multimeter is no longer necessary. The linear two-quadrant design of the output stages allows the R&S®NGL200 power supply series to operate as a source and sink with minimum residual ripple and noise, ideally supporting the development of power amplifiers and MMICs.


      Available models
      ModelsNumber of output channelsMax. output powerOutput voltage per channelOutput current per channel
      R&S®NGL201160 W0 V to 20 V≤ 6 V: 0 A to 6 A
      > 6 V: 0 A to 3 A
      R&S®NGL2022120 W0 V to 20 V≤ 6 V: 0 A to 6 A
      > 6 V: 0 A to 3 A
      Features
      • Technology for challenging tasks
        • Fast load regulation
        • Minimum residual ripple and low noise
        • Readings with up to 6½ digit resolution
        • Galvanically isolated, floating channels
        • Output stage isolated with relays
        • Two quadrants: operates as source and sink
        • Constant voltage, constant current and constant resistance modes
        • Variable internal impedance
        • Protection functions to safeguard instrument and DUT
        • Safety limits to safeguard the DUT

      • Easy operation
        • High-resolution touchscreen
        • Color coding of operating modes
        • QuickArb function
        • EasyRamp function
        • Save and recall instrument settings

      • Ideal for use in labs and test systems
        • Tailored for use in labs and system racks
        • Sense function for lead resistance compensation
        • Front and rear connectors
        • Full remote capabilities
        • Fast on the bus and on the bench
        • Advanced instrument design: compact form factor, quiet operation

      Specifications
      Electrical specifications
      OutputsThe channel outputs are galvanically isolated and not connected to ground.
      Number of output channels R&S®NGL2011
      R&S®NGL2022
      Total output power R&S®NGL201max. 60 W
      R&S®NGL202max. 120 W
      Maximum output power per channel60 W
      Output voltage per channel 0 V to 20 V
      Maximum output current per channel ≤ 6 V output voltage6 A
      > 6 V output voltage3 A
      Maximum voltage in serial operationR&S®NGL20240 V
      Maximum current in parallel operationR&S®NGL202, ≤ 6 V output voltage12 A
      R&S®NGL202, > 6 V output voltage6 A
      Adjustable output impedance–50 mΩ to 100 Ω
        Increments 1 mΩ
      Voltage ripple and noise20 Hz to 20 MHz< 500 µV (RMS),
      < 2 mV (peak-to-peak) (meas.)
      Current ripple and noise20 Hz to 20 MHz< 1 mA (RMS) (meas.)
      Electronic load yes, R&S®NGL202: both channels
        Maximum sink power R&S®NGL20160 W
      R&S®NGL202120 W (60 W per channel) 1)
      1)  Time limited at an operating temperature of > 30°C and total power > 90 W.
        Maximum sink current per channel 3 A
        Sink modesconstant voltage, constant current, constant resistance
      Load regulationload change: 10% to 90%
      Voltage±(% of output + offset)< 0.01% + 0.5 mV
      Current±(% of output + offset) < 0.01% + 0.1 mA
      Load recovery timeregulation to within ±20 mV of the set voltage< 30 µs (meas.)
      Programming resolution
      Voltage1 mV
      Current0.1 mA
      Programming accuracy
      Voltage±(% of the output + offset) < 0.02% + 3 mV
      Current±(% of the output + offset) < 0.05% + 2 mA
      Output measurements
      Measurement functionsvoltage, current, power, energy
      Readback resolution
      Voltage 10 μV
      Current 10 μA
      Readback accuracy
      Voltage±(% of output + offset)< 0.02% + 2 mV
      Current ±(% of output + offset) < 0.05% + 250 μA
      Temperature coefficient (per °C)+23 °C (–3 °C/+7 °C)
        Voltage±(% of output + offset)0.15 × specification/°C
        Current±(% of output + offset)0.15 × specification/°C
      Sense functionyes, R&S®NGL202: both channels
        Maximum sense compensation2 V
      Ratings
      Maximum voltage to ground 250 V DC
      Maximum counter voltagevoltage with the same polarity connected to the outputs22 V
      Maximum reverse voltagevoltage with opposite polarity connected to the outputs0.5 V
      Maximum reverse current for 5 minutes max.1 A
      Remote control
      Command processing timetyp. < 6 ms
      Protection functions
      Overvoltage protection adjustable, R&S®NGL202: both channels
        Programming resolution1 mV
      Overpower protection adjustable, R&S®NGL202: both channels
      Overcurrent protection (electronic fuse)adjustable, R&S®NGL202: both channels
      Programming resolution0.1 mA
        Response time(Iload > Iresp × 2) at Iload ≥ 2 A< 1.5 ms
        Fuse linking (FuseLink function) R&S®NGL202yes
        Fuse delay at output-on for R&S®NGL202: both channels0 ms to 10 s (1 ms increments)
        Fuse delay timefor R&S®NGL202: both channels0 ms to 10 s (1 ms increments)
      Overtemperature protection yes
      Special functions
      Output ramp functionEasyRamp
      EasyRamp time 10 ms to 10 s (10 ms increments)
      10 ms to 10 s (10 ms increments)
      Synchronicitytyp. < 25 μs
      Delay per channel1 ms to 10 s (1 ms increments)
      Arbitrary functionQuickArb
      Parameters voltage, current, time
      Maximum number of points 4096
      Dwell time 1 ms to 20 h (1 ms increments)
      Repetitioncontinuous or burst mode with 1 to 65535 repetitions
      Trigger manually via the keyboard, via remote control or via optional interface
      Trigger and control interfacesdigital I/O, R&S®NGL-K103
      Display and interfaces
      DisplayTFT 5" 800 × 480 pixels WVGA Touch
      Front panel connectionsR&S®NGL2014 mm safety sockets (channels, sense)
      R&S®NGL2024 mm safety sockets (channels)
      Rear panel connections8-pin connector block per channel
      Remote control interfacesStandardUSB-TMC, USB-CDC (virtual COM port), LAN
      R&S®NGL-K102WLAN
      R&S®NGL-B105IEEE-488 (GPIB)
      General data
      Environmental conditions
      Temperatureoperating temperature range +5°C to +40°C
      storage temperature range–20°C to +70°C
      HumidityNoncondensing5% to 95%
      Power rating
      Mains nominal voltage 100 V/115 V/230 V (±10%)
      Mains frequency50 Hz to 60 Hz
      Maximum power consumption 400 W
      Mains fuses2 × T4.0H/250 V
      Product conformity
      Electromagnetic compatibilityEU: in line with Radio Equipment Directive 2014/53/EUapplied standards:
      ETSI EN300 328 V2.1.1
      EN 61326-1
      EN55011 (Class A)
      EN55032 (Class A)
      ETSI EN301 489-1 V2.2.0
      ETSI EN301 489-17 V3.2.0
      Korea KC mark
      Electrical safetyEU: in line with Low Voltage Directive 2014/35/EUapplied harmonized standards: EN 61010-1
      USA, CanadaCSA-C22.2 No. 61010-1
      WLAN approvalsAustria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United KingdomCE0682
      SingaporeiMDA standards DB102020
      USA, CanadaFCC, IC
      RoHSin line with EU Directive 2011/65/EUEN50581
      Mechanical resistance
      VibrationSinusoidal5 Hz to 55 Hz, 0.3 mm (peak-to-peak) 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6
      Wideband noise8 Hz to 500 Hz, acceleration: 1.2 g (RMS) in line with EN 60068-2-64
      Shock40 g shock spectrum, in line with MIL-STD-810E, method 516.4, procedure I
      Mechanical data
      DimensionsW × H × D222 mm × 97 mm × 436 mm (8.74 in x 3.82 in x 17.17 in)
      WeightR&S®NGL2017.1 kg (15.6 lb)
      R&S®NGL2027.3 kg (16.1 lb)
      Rack installation R&S®HZN96 option
      Recommended calibration intervaloperation 40 h/week over entire range of specified environmental conditions1 year