Maximum output power | 100 W |
Maximum output power per channel |
R&S® HMC8043 | 33 W |
R&S® HMC8042 | 50 W |
R&S® HMC8041 | 100 W |
Output voltage per channel |
all models | 0 V to 32 V |
Maximum output current per channel |
R&S® HMC8043 | 3 A |
R&S® HMC8042 | 5 A |
R&S® HMC8041 | 10 A |
Number of output channels |
R&S® HMC8043 | 3 |
R&S® HMC8042 | 2 |
R&S® HMC8041 | 1 |
Line & load regulation |
Voltage |
R&S® HMC8043 | < 0.02% + 3 mV (meas.) |
R&S® HMC8042 | < 0.03% + 5 mV (meas.) |
R&S® HMC8041 | < 0.03% + 5 mV (meas.) |
Current |
R&S® HMC8043 | < 0.03% + 200 µA (meas.) |
R&S® HMC8042 | < 0.03% + 300 µA (meas.) |
R&S® HMC8041 | < 0.03% + 300 µA (meas.) |
Load recovery time (10% to 90% load change) | < 1 ms (meas.) (to within a band of ±20 mV of the set voltage) |
Voltage ripple and noise (20 Hz to 20 MHz) |
R&S® HMC8043 | < 450 µV (RMS) /< 4 mV (peak to peak) (meas.) |
R&S® HMC8042 | < 450 µV (RMS) /< 4 mV (peak to peak) (meas.) |
R&S® HMC8041 | < 1 mV (RMS) /< 5 mV (peak to peak) (meas.) |
Current ripple and noise (20 Hz to 20 MHz) |
R&S® HMC8043 | < 1 mA (RMS) (meas.) |
R&S® HMC8042 | < 1 mA (RMS) (meas.) |
R&S® HMC8041 | < 1.5 mA (RMS) (meas.) |
Max SENSE compensation | 1 V (meas.) |
Programming accuracy (+23°C ±5°C) |
Voltage |
all models | < 0.05% + 2 mV |
Current |
R&S® HMC8043 | < 0.05% + 2 mA |
R&S® HMC8042 | < 0.1% + 5 mA |
R&S® HMC8041 | < 0.2% +10 mA |
Readback accuracy (+23°C ±5°C) |
Voltage |
all models | < 0.05% + 2 mV |
Current |
R&S® HMC8043 | < 0.05% + 2 mA |
R&S® HMC8042 | < 0.05% + 4 mA |
R&S® HMC8041 | < 0.15% + 10 mA |
Resolution |
Voltage |
all models | 1mV |
Current |
R&S® HMC8043 | I < 1 A: 0.1 mA |
R&S® HMC8042 | I ≥ 1 A: 1 mA |
R&S® HMC8041 | I < 1 A: 0.5 mA I ≥ 1 A: 1 mA |
Maximum voltage to ground | 250 V DC |
Maximum counter voltage | 33 V |
Meximum reverse voltage | 0.4 V |
Maximum reverse current | 3 A |
Supplemental characteristics |
Front connectors | 4 mm safety sockets |
Rear connectors | Wago male connector (713-1428/037- 000), 8 x 2-pole, pin spacing 3.5mm / 0.138in |
Temperature coefficient ± (% of output + offset) (per °C) | voltage: < 0.02% + 3 mV current: < 0.02% + 3 mA |
Output voltage overshoot during turn-off of AC power with activated channel output | < 100 mV (meas.) |
Over temperature protection | yes |
Voltage programming time (within 1% of total excursion) |
Positive voltage change |
no load | 10 ms + command processing-time |
with resistive load | 10ms + command processing-time |
Negative voltage change |
no load | 500ms + command processing-time |
with resistive load | 10ms + command processing-time |
Command processing time | < 30ms (nom.) |
Over voltage protection | Yes |
Over power protection | Yes |
Energy Meter | Yes |
EasyRamp | Yes |
EasyRamp time | 10ms to 10 s |
Electronic fuse |
Fuse response time | < 10 ms (meas.) |
Response time of linked channels | < 100 µs (meas.) + response time of linked channel |
Fuse delay | 10 ms to 10 s |
Analog control interface |
Control parameter | voltage or current |
Current / shunt resistance | 4 mA to 20 mA / 250 Ω |
Input voltage / max. resistance | 0 V to 10 V / 10kΩ |
Acquisition rate V/I interface | 10 sample/s |
Maximum response time | 150ms |
Resolution | 14 bit |
Trigger input |
Trigger response time | < 1ms (meas.) |
Min. trigger interval | 10 ms |
Input level | TTL |
Edge direction | rising, falling |
Arbitrary (EasyArb) |
Parameter | Voltage, current, time |
Maximum number of points | 512 |
Dwell time | 10 ms to 600 s |
Repetition rate | continuous or burst mode with 1 to 255 repetitions |
Trigger | manually, remote control or via trigger input |