| Outputs | All channel outputs are galvanically isolated and not connected to ground. |
| Number of output channels | R&S®NGE102B | 2 |
| R&S®NGE103B | 3 |
| Total output power | R&S®NGE102B | max. 66 W |
| R&S®NGE103B | max. 100 W |
| Maximum output power | per channel | 33.6 W |
| Output voltage | per channel | 0 V to 32 V |
| Maximum output current | per channel | 3 A |
| Maximum voltage in serial operation | R&S®NGE102B | 64 V |
| R&S®NGE103B | 96 V |
| Maximum current in parallel operation | R&S®NGE102B | 6 A |
| R&S®NGE103B | 9 A |
| Voltage ripple and noise | 20 Hz to 20 MHz | typ. < 1.5 mV (RMS) < 20 mV (peak-to-peak) (meas.) |
| Current ripple and noise | 20 Hz to 20 MHz | < 2 mA (RMS) (meas.) |
| Load regulation | load change from 10% to 90% | |
| Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
| Current | ± (% of output + offset) | < 0.1% + 5 mA |
| Load recovery time | 10% to 90% load change within a band of ± 30 mV of set voltage | < 200 µs (meas.) |
| Line regulation | ±10% change in mains voltage | |
| Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
| Current | ± (% of output + offset) | < 0.1% + 5 mA |
| Output voltage overshoot at turn-off of mains power and active channel output | | < 100 mV |
| Programming resolution | | |
| Voltage | | 10 mV |
| Current | | 1 mA |
| Programming accuracy | | |
| Voltage | ± (% of output + offset) | < 0.1% + 30 mV |
| Current | ± (% of output + offset) | < 0.1% + 5 mA |
| Output measurements |
| Measurement functions | | voltage, current, power |
| Readback resolution | | |
| Voltage | | 10 mV |
| Current | | 1 mA |
| Readback accuracy | | |
| Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
| Current | ± (% of output + offset) | < 0.1% + 5 mA |
| Temperature coefficient | +5°C to +20°C and +30°C to +40°C |
| Voltage | ± (% of output + offset) | < 0.02% + 5 mV per K |
| Current | ± (% of output + offset) | < 0.02% + 3 mA per K |
| Ratings |
| Maximum voltage to earth | | 150 V DC |
| Maximum counter voltage | voltage with same polarity connected to the outputs | 33 V |
| Maximum reverse voltage | voltage with opposite polarity connected to the outputs | 0.4 V |
| Maximum reverse current | | 3 A |
| Remote control |
| Command processing time | | ≤ 30 ms |
| Programming settling time | within 1% of final value | |
| Positive voltage change | no load | 10 ms + command processing time |
| full load (resistive) | 10 ms + command processing time |
| Negative voltage change | no load | 500 ms + command processing time |
| full load (resistive) | 10 ms + command processing time |
| Protection functions |
| Overvoltage protection | | configurable for each channel |
| Overpower protection | | configurable for each channel |
| Overcurrent protection (electronic fuse) | | configurable for each channel |
| Response time | (Iload > Iresp × 2) | < 10 ms |
| Fuse linking (FuseLink function) | | Yes |
| Response time of linked channels | | < 100 µs + response time of linked channel |
| Fuse delay | configurable for each channel | 10 ms to 10 s (10 ms increments) |
| Overtemperature protection | | Yes |
| Special functions |
| Output ramp function | | EasyRamp |
| EasyRamp time | | 10 ms to 10 s (10 ms increments) |
| Arbitrary function | | EasyArb |
| Parameter | | voltage, current, time |
| Maximum number of points | | 128 |
| Dwell time | | 10 ms to 600 s (10 ms increments) |
| Repetition | | continuous or burst mode with 1 to 255 repetitions |
| Trigger | optional (R&S®NGE-K103) | manually, remote control or via optional trigger input |
| Trigger and control interface | optional (R&S®NGE-K103) | digital I/O |
| Minimum trigger interval | | 10 ms |
| Trigger response time | | < 150 ms |
| Trigger level | | TTL, max. 5 V |
| Edge direction | | rising, falling |
| Display and interfaces |
| Display | | 3.5"/QVGA |
| Front panel connections channel outputs | | 4 mm safety binding posts |
| Remote control interfaces | Standard | USB-TMC, USB-CDC (virtual COM) |
| optional (R&S®NGE-K101) | LAN (LXI) |
| optional (R&S®NGE-K102) | wireless LAN 802.11 b/g/n, 2.4 GHz; operating mode: client |
| Trigger and control interface | optional (R&S®NGE-K103) | digital I/O |
| General data |
| Environmental conditions | | |
| Temperature | operating temperature range | 0°C to +40°C |
| storage temperature range | –20°C to +70° |
| Humidity | noncondensing | 5% to 80% |
| Power rating | | |
| Mains nominal voltage | | 115 V/230 V (± 10%) |
| Mains frequency | | 50 Hz/60 Hz |
| Maximum power consumption | | 180 W |
| Mains fuses | 115 V AC power source | IEC60127-2/5 T 5 A 250 V |
| 230 V AC power source | IEC60127-2/5 T 2.5 A 250 V |
| Product conformity | | |
| Electromagnetic compatibility | EU, in line with EU RE Directive 2014/53/EU (notified body: CTC advanced GmbH) | applied standards: EN61326-1, EN61326-2-1, DRAFT EN301489-1 V 2.2.0, DRAFT EN301489-17 V 3.2.0, EN300328 V 2.1.1, 47 CFR FCC part 15B (class A), and ICES-003 issue 6 |
| Korea | KC mark |
| Electrical safety | EU, in line with Low Voltage Directive 2014/35/EU | EN61010-1 |
| USA | UL 61010-1 |
| Canada | CSA C22.2 No. 61010-1 |
| Wireless LAN certifications | Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom | CE |
| Singapore | iMDA standards DB102020 |
| United States, Canada | FCC, IC |
| RoHS | | EN50581, in line with EU directive 2011/65/EU |
| International safety approvals | cTUVus mark | certificate no. U8 18 04 87787 008 |
| Mechanical resistance | | |
| Vibration | Sinusoidal | 5 Hz to 55 Hz, 0.30 mm (peak-to-peak) amplitude const., 55 Hz to 155 Hz, 0.5 g const., in line with EN60068-2-6 |
| Random | 8 Hz to 500 Hz, 1.2 g (RMS), in all three axes, in line with EN60068-2-64 |
| Shock | | 10 Hz to 45 Hz, ramp 6 dB/octave, 45 Hz to 2000 Hz: max. 40 g in line with MIL-STD-810E |
| Mechanical data | | |
| Dimensions | W × H × D | 222 mm × 97 mm × 310 mm (8.74 in × 3.82 in × 12.21 in) |
| Weight | R&S®NGE102B | 4.9 kg (10.80 lb) |
| R&S®NGE103B | 5.0 kg (11.00 lb) |
| Rack installation | optional (R&S®HZC95) | ½ 19" |
| Recommended calibration interval | operation 40 h/week in the full range of the specified environmental conditions | 1 year |