Outputs | All channel outputs are galvanically isolated and not connected to ground. |
Number of output channels | R&S®NGE102B | 2 |
| R&S®NGE103B | 3 |
Total output power | R&S®NGE102B | max. 66 W |
| R&S®NGE103B | max. 100 W |
Maximum output power | per channel | 33.6 W |
Output voltage | per channel | 0 V to 32 V |
Maximum output current | per channel | 3 A |
Maximum voltage in serial operation | R&S®NGE102B | 64 V |
| R&S®NGE103B | 96 V |
Maximum current in parallel operation | R&S®NGE102B | 6 A |
| R&S®NGE103B | 9 A |
Voltage ripple and noise | 20 Hz to 20 MHz | typ. < 1.5 mV (RMS) < 20 mV (peak-to-peak) (meas.) |
Current ripple and noise | 20 Hz to 20 MHz | < 2 mA (RMS) (meas.) |
Load regulation | load change from 10% to 90% | |
Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
Current | ± (% of output + offset) | < 0.1% + 5 mA |
Load recovery time | 10% to 90% load change within a band of ± 30 mV of set voltage | < 200 µs (meas.) |
Line regulation | ±10% change in mains voltage | |
Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
Current | ± (% of output + offset) | < 0.1% + 5 mA |
Output voltage overshoot at turn-off of mains power and active channel output | | < 100 mV |
Programming resolution | | |
Voltage | | 10 mV |
Current | | 1 mA |
Programming accuracy | | |
Voltage | ± (% of output + offset) | < 0.1% + 30 mV |
Current | ± (% of output + offset) | < 0.1% + 5 mA |
Output measurements |
Measurement functions | | voltage, current, power |
Readback resolution | | |
Voltage | | 10 mV |
Current | | 1 mA |
Readback accuracy | | |
Voltage | ± (% of output + offset) | < 0.1% + 20 mV |
Current | ± (% of output + offset) | < 0.1% + 5 mA |
Temperature coefficient | +5°C to +20°C and +30°C to +40°C |
Voltage | ± (% of output + offset) | < 0.02% + 5 mV per K |
Current | ± (% of output + offset) | < 0.02% + 3 mA per K |
Ratings |
Maximum voltage to earth | | 150 V DC |
Maximum counter voltage | voltage with same polarity connected to the outputs | 33 V |
Maximum reverse voltage | voltage with opposite polarity connected to the outputs | 0.4 V |
Maximum reverse current | | 3 A |
Remote control |
Command processing time | | ≤ 30 ms |
Programming settling time | within 1% of final value | |
Positive voltage change | no load | 10 ms + command processing time |
| full load (resistive) | 10 ms + command processing time |
Negative voltage change | no load | 500 ms + command processing time |
| full load (resistive) | 10 ms + command processing time |
Protection functions |
Overvoltage protection | | configurable for each channel |
Overpower protection | | configurable for each channel |
Overcurrent protection (electronic fuse) | | configurable for each channel |
Response time | (Iload > Iresp × 2) | < 10 ms |
Fuse linking (FuseLink function) | | Yes |
Response time of linked channels | | < 100 µs + response time of linked channel |
Fuse delay | configurable for each channel | 10 ms to 10 s (10 ms increments) |
Overtemperature protection | | Yes |
Special functions |
Output ramp function | | EasyRamp |
EasyRamp time | | 10 ms to 10 s (10 ms increments) |
Arbitrary function | | EasyArb |
Parameter | | voltage, current, time |
Maximum number of points | | 128 |
Dwell time | | 10 ms to 600 s (10 ms increments) |
Repetition | | continuous or burst mode with 1 to 255 repetitions |
Trigger | optional (R&S®NGE-K103) | manually, remote control or via optional trigger input |
Trigger and control interface | optional (R&S®NGE-K103) | digital I/O |
Minimum trigger interval | | 10 ms |
Trigger response time | | < 150 ms |
Trigger level | | TTL, max. 5 V |
Edge direction | | rising, falling |
Display and interfaces |
Display | | 3.5"/QVGA |
Front panel connections channel outputs | | 4 mm safety binding posts |
Remote control interfaces | Standard | USB-TMC, USB-CDC (virtual COM) |
| optional (R&S®NGE-K101) | LAN (LXI) |
| optional (R&S®NGE-K102) | wireless LAN 802.11 b/g/n, 2.4 GHz; operating mode: client |
Trigger and control interface | optional (R&S®NGE-K103) | digital I/O |
General data |
Environmental conditions | | |
Temperature | operating temperature range | 0°C to +40°C |
| storage temperature range | –20°C to +70° |
Humidity | noncondensing | 5% to 80% |
Power rating | | |
Mains nominal voltage | | 115 V/230 V (± 10%) |
Mains frequency | | 50 Hz/60 Hz |
Maximum power consumption | | 180 W |
Mains fuses | 115 V AC power source | IEC60127-2/5 T 5 A 250 V |
| 230 V AC power source | IEC60127-2/5 T 2.5 A 250 V |
Product conformity | | |
Electromagnetic compatibility | EU, in line with EU RE Directive 2014/53/EU (notified body: CTC advanced GmbH) | applied standards: EN61326-1, EN61326-2-1, DRAFT EN301489-1 V 2.2.0, DRAFT EN301489-17 V 3.2.0, EN300328 V 2.1.1, 47 CFR FCC part 15B (class A), and ICES-003 issue 6 |
| Korea | KC mark |
Electrical safety | EU, in line with Low Voltage Directive 2014/35/EU | EN61010-1 |
| USA | UL 61010-1 |
| Canada | CSA C22.2 No. 61010-1 |
Wireless LAN certifications | Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom | CE |
| Singapore | iMDA standards DB102020 |
| United States, Canada | FCC, IC |
RoHS | | EN50581, in line with EU directive 2011/65/EU |
International safety approvals | cTUVus mark | certificate no. U8 18 04 87787 008 |
Mechanical resistance | | |
Vibration | Sinusoidal | 5 Hz to 55 Hz, 0.30 mm (peak-to-peak) amplitude const., 55 Hz to 155 Hz, 0.5 g const., in line with EN60068-2-6 |
| Random | 8 Hz to 500 Hz, 1.2 g (RMS), in all three axes, in line with EN60068-2-64 |
Shock | | 10 Hz to 45 Hz, ramp 6 dB/octave, 45 Hz to 2000 Hz: max. 40 g in line with MIL-STD-810E |
Mechanical data | | |
Dimensions | W × H × D | 222 mm × 97 mm × 310 mm (8.74 in × 3.82 in × 12.21 in) |
Weight | R&S®NGE102B | 4.9 kg (10.80 lb) |
| R&S®NGE103B | 5.0 kg (11.00 lb) |
Rack installation | optional (R&S®HZC95) | ½ 19" |
Recommended calibration interval | operation 40 h/week in the full range of the specified environmental conditions | 1 year |