產品明細

SMCV100B

向量信號產生器

    產品簡述
    ♦ 支援多標準數位電視信號(DVB-H/DVB-T, DAB/T-DMB, DVB-S2/DVB-S2X, OFDM signal generation), 衛星導航信號(GPS, Galileo, GLONASS, Beidou), 行動通訊信號(3GPP, EUTRA/LTE Release 12, Cellular loT, Verizon 5GTF signals, LTE Release 13 and 14, Cellular loT enhancements, 5G NR, Cellular loT Release 15) 及無線通訊應用(IEEE 802.11, Bluetooth EDR, IEEE 802.11ac, Bluetooth 5.0, LORA, IEEE 802.11ax)
    頻率範圍: 4kHz~7.125GHz
    功率範圍: -145~+25dBm
    調變頻寬: 最大240MHz

      產品詳細介紹Product Introduction

      Highest flexibility in applications and production

      The R&S®SMCV100B vector signal generator is the first multistandard platform for automotive, broadcast, navigation and wireless applications. This makes the R&S®SMCV100B unique for use in many applications, from the lab to production and wherever different technologies meet.
      The R&S®SMCV100B vector signal generator features a new direct RF DAC concept for RF signal generation. This concept enables I/Q modulation and upconversion in the digital domain, which eliminates the I and Q imbalance errors and LO leakage associated with traditional analog I/Q modulators. The R&S®SMCV100B options concept is fully software defined. No hardware options are required to obtain full instrument functionality. This software concept applies to upgrading the RF frequency, memory, I/Q modulation bandwidth and all other R&S®SMCV100B options for other applications. Thanks to its flexible and customizable design, the instrument is ready to meet future requirements. Options can easily be added via software keycodes, allowing users to quickly upgrade functions and add bandwidth, output power and even frequency range. The intuitive, touchscreen based operating concept makes the R&S®SMCV100B very ergonomic and practical to use.


      Features
      • First multistandard platform for broadcast, navigation, cellular and wireless applications
      • Fully software defined vector signal generator with software based option concept
      • Modern RF signal generation concept with direct digital RF upconversion up to 2.5 GHz
      • High output power up to +25 dBm
      • Modulation bandwidth up to 240 MHz
      • Convenient operation on 5" touchscreen

      Specifications
      Frequency
      Rangewith R&S®SMCVB-B103 option (mandatory)4 kHz to 3 GHz
      with R&S®SMCVB-B103 and R&S®SMCVB-KB106 options4 kHz to 6 GHz
      with R&S®SMCVB-B103, R&S®SMCVB-KB106 and R&S®SMCVB-KB107 options4 kHz to 7.125 GHz
      Resolution of setting0.001 Hz
      Resolution of synthesisf = 1 GHz2.665 μHz (nom.)
      Settling timeto within < 1 × 10–7 for f > 200 MHz or < 20 Hz for f ≤ 200 MHz with GUI update stopped, I/Q optimization mode: fast, measured from command at instrument to frequency settled within specified range, with Ethernet (fast socket) remote control, level setting characteristic: auto< 5 ms
      Range and resolution of phase offset setting–999.99° to +999.99°, 0.01° resolution
      Reference frequency
      Frequency errorat time of calibration in production< 1 × 10–7
      Agingafter 30 days of uninterrupted operation≤ 1 × 10–6 /year
      Temperature effectin temperature range from +5 °C to +45 °C ±1.0 × 10–6
      Sourceinternal, external
      External reference frequency modes Standard10 MHz
      Reference frequency input
      Connector typeREF IN on rear panel BNC female
      Input frequency10 MHz, 13 MHz
      Minimum frequency locking range± 25 × 10–6 (meas.)
      Input level range0 dBm to +16 dBm (meas.)
      Input impedance50 Ω (nom.)
      Reference frequency output
      Connector typeREF OUT on rear panel BNC female
      Output frequencysquare wave
         source mode: internal 10 MHz
         source mode: external 10 MHz
      Output level+7 dBm to +13 dBm, +10 dBm (meas.)
      Source impedance50 Ω (nom.)
      Level
      Setting range
      R&S®SMCVB-B103/-KB106/-KB107Standard
         4 kHz ≤ f < 100 kHz–120 dBm to +16 dBm
         100 kHz ≤ f < 6 GHz–145 dBm to +16 dBm
         6 GHz ≤ f ≤ 7.125 GHz–145 dBm to +16 dBm
      with R&S®SMCVB-K31 option
         4 kHz ≤ f < 100 kHz–120 dBm to +25 dBm
         100 kHz ≤ f ≤ 6 GHz–145 dBm to +25 dBm
         6 GHz ≤ f ≤ 7.125 GHz–145 dBm to +25 dBm
      Setting resolution0.01 dB
      Specified level rangepeak envelope power (PEP)
      R&S®SMCVB-B103/-KB106/-KB107Standard
         4 kHz < f ≤ 10 MHz –110 dBm to +15 dBm
         10 MHz < f ≤ 6 GHz 1–120 dBm to +15 dBm
         6 GHz < f ≤ 7.125 GHz–120 dBm to +15 dBm
      with R&S®SMCVB-K31 option
         4 kHz < f ≤ 10 MHz–110 dBm to +20 dBm
         10 MHz < f ≤ 6 GHz 1–120 dBm to +20 dBm
         6 GHz < f ≤ 7.125 GHz–120 dBm to +18 dBm
      Level accuracylevel setting characteristic: auto, temperature range from +18 °C to +33 °C
      level > –80 dBm
         4 kHz < f < 200 kHz< 1.8 dB
         200 kHz ≤ f ≤ 10 MHz< 0.7 dB
         10 MHz < f ≤ 2.5 GHz 1 < 0.5 dB
         f > 2.5 GHz 1< 0.7 dB
      level ≤ –80 dBm
         4 kHz < f < 200 kHz< 1.8 dB
         200 kHz ≤ f ≤ 10 MHz< 1.2 dB, < 1.0 dB (typ.)
         10 MHz < f ≤ 2.5 GHz 1 < 0.8 dB
         f > 2.5 GHz 1< 1.1 dB
      Settling timeto < 0.1 dB deviation from final value, with GUI update stopped, temperature range from +18 °C to +33 °C, f > 10 MHz, I/Q optimization mode: fast, measured from command at instrument to frequency settled within specified range, with Ethernet (fast socket) remote control, level setting characteristic: auto< 5 ms
      Interruption-free level rangelevel setting characteristic: uninterrupted level setting> 20 dB
      1 For multiples of f = 0.5 GHz, specified level range is limited to –100 dBm due to a discrete spurious.
      Reverse power
      Reverse powermaximum permissible RF power in output frequency range of RF path, from 50 Ω source; In case of too high reverse power, the RF output is switched off.
      1 MHz < f ≤ 7.125 GHz2 W
      Maximum permissible DC voltage35 V (nom.)
      VSWR
      Output impedance VSWR in 50 Ω systemevel setting characteristic: auto, f > 200 kHz
      Pout ≤ 5 dBm< 2.0
      Pout > 5 dBm
         200 kHz < f ≤ 4.5 GHz< 2.0 (typ.)
         4.5 GHz < f ≤ 6 GHz< 2.5 (typ.)
      Spectral purity
      HarmonicsCW, I/Q mode (full-scale internal single carrier signal), level ≤ 13 dBm
      1 MHz < f ≤ 7.125 GHz< –30 dBc
      Nonharmonics CW, level > +10 dBm, > 10 kHz offset from carrier and outside the modulation spectrum, reference frequency internal
         f ≤ 2.5 GHz < –52 dBc, –60 dBc (typ.)
         2.5 GHz < f ≤ 7.125 GHz< –52 dBc, –70 dBc (typ.)
      Wideband noiseCW, level = +10 dBm, carrier offset = 30 MHz, measurement bandwidth 1 Hz
         20 MHz ≤ f ≤ 100 MHz< –139 dBc
         100 MHz < f ≤ 2.5 GHz< –142 dBc
         2.5 GHz < f ≤ 7.125 GHz< –133 dBc
      SSB phase noisecarrier offset = 20 kHz, measurement bandwidth 1 Hz, level = +10 dBm
         f = 100 MHz< –110 dBc
         f = 1 GHz< –100 dBc
         f = 2 GHz< –100 dBc
         f = 2.5 GHz< –100 dBc
         2.5 GHz < f ≤ 7.125 GHz< –95 dBc
      SSB phase noise with R&S®SMCVB-K709 optioncarrier offset = 20 kHz, measurement bandwidth 1 Hz, level = +10 dBm
         f = 100 MHz < –145 dBc
         f = 1 GHz< –125 dBc
         f = 2 GHz< –119 dBc
         f = 2.5 GHz< –117 dBc
         2.5 GHz < f ≤ 7.125 GHz< –107 dBc
      Residual FMCW, RMS values at f = 1 GHz 2
         300 Hz to 3 kHz, weighted (ITU-T) < 2 Hz, 0.63 Hz (typ.)
         20 Hz to 23 kHz< 16 Hz, 8.15 Hz (typ.)
      Residual FM with R&S®SMCVB-K709 optionCW, RMS values at f = 1 GHz 2
         300 Hz to 3 kHz, weighted (ITU-T)< 2 Hz, 0.15 Hz (typ.)
         20 Hz to 23 kHz< 4 Hz, 1.9 Hz (typ.)
      Residual AMCW, f > 10 MHz, RMS value (20 Hz to 20 kHz), level = 12 dBm
         4 kHz ≤ f ≤ 100 MHz < 0.08 %
         100 MHz < f ≤ 7.125 GHz< 0.05 %
      Frequency and level sweep
      Operating modedigital sweep in discrete steps
      Sweep parametersRF frequency, RF level
      Trigger modesexecute sweep continuously with internal trigger sourceauto
      execute one full sweepsingle, extern single
      execute one step step, extern step
      sweep start and stop controlled by external trigger signalextern start/stop
      Trigger sourceexternal trigger signal (user 1 or user 2 at rear), rotary knob, touch panel, remote control
      Sweep rangefully specified frequency and level range
      interruption-free level sweep with level setting characteristic: uninterrupted level setting0.01 dB to 20 Db
      Sweep shapesawtooth, triangle
      Step size setting resolutionfrequency sweep linear0.001 Hz
      frequency sweep logarithmic 0.01 %
      level sweep0.01 dB
      Dwell time setting range5 ms to 100 s
      Dwell time setting resolution0.1 ms
      I/Q modulation performance
      Operating modesinternal baseband I/Q
      RF modulation bandwidthThe maximum signal bandwidth depends on the baseband option configuration, see I/Q baseband generator.
         8 kHz < f ≤ 240 MHz±50 % of carrier frequency
         f > 240 MHz±120 MHz
      RF frequency response in specified RF modulation bandwidth standard, up to 120 MHz RF modulation bandwidth< 3.5 dB, < 2.5 dB (meas.)
      with R&S®SMCVB-K547 option, optimization mode: high quality, up to 240 MHz RF modulation bandwidth< 1.2 dB, < 0.3 dB (meas.)
      Carrier leakagemode: internal baseband I/Q, referenced to full-scale input< –60 dBc, < –80 dBc (meas.)
      Suppression of image sideband for entire instrument in modulation bandwidth up to 240 MHz RF modulation bandwidth> 75 dB (meas.)